Server room CFD analyses results

Open data API in a single place

Provided by Zenodo

Get early access to Server room CFD analyses results API!

Let us know and we will figure it out for you.

Dataset information

Country of origin
Updated
2020.01.24 00:00
Created
2020.01.01
Available languages
English
Keywords
CFD, server room, heat exchange, data center cooling, air cooling
Quality scoring

Dataset description

Files included in this dataset contain transient records of the most important variables of results of 9 scenarios of Poznan Supercomputing and Networking Center testbed CFD analysis. Modeled testbed included server room equipped with two heterogeneously occupied racks (with each server modeled separately) and one roof-mounted cooling device. Setup was examined virtually for three servers power usage scenarios (50%, 75% and 100% of maximum value). For major part of active servers the power usage was changed respectively in each scenario, while some of them preserved daily-averaged values (inactive devices are also included). For each power usage level also three different air conditioning temperature setups (24, 27 and 30 Celsius degrees) were tested. The most relevant information about the model can be found below:   server room dimensions along x, y and z axis (with one of the corners placed in the origin): (4.86, 4.00, 3.00) [m] racks dimensions: (0.6,1.18,2.1),(0.8,1.18,2.2) [m] racks position (translation from 0,0,0): (1.4,1.95,0), (2.08,1.95,0) [m] first rack equipment (position [-], size [-], airflow [m3/s], power usage (50%/75%/100% scenario) [W], flow orientation [-]): 0, plug, -, -/-/-, -, 1, plug, -, -/-/-, -, 2, 4U, 0.0, 0.0/0.0/0.0, y, 6, 2U, 0.0, 0.0/0.0/0.0, y, 9, plug, -, -/-/-, -, 10, 2U, 0.05, 230/345/460, y, 20, 2U, 0.025, 90/90/90, y, 22, 2U, 0.05,  450/675/900, y, 24, 4U, 0.12, 1000/1500/2000, y, 28, 2U, 0.05,  230/345/460, y, 30, 4U, 0.12, 1000/1500/2000, y, 34, 2U, 0.05,  400/600/800, y, 36, 2U, 0.05,  400/600/800, y, second rack equipment (position [-], size [-], airflow [m3/s], power usage (50%/75%/100%  scenario) [W], flow orientation [-]): 0, 3U, 0.0, 0.0/0.0/0.0, y, 3, 3U, 0.0, 0.0/0.0/0.0, y, 6, plug, -, -/-/-, -, 7, plug, -, -/-/-, -, 8, 3U, 0.0, 0.0/0.0/0.0, y, 11, 2U, 0.0, 0.0/0.0/0.0, y, 13, 2U, 0.025, 69/69/69, x, 15, 3U, 0.0/0.0/0.0, 0.0/0.0/0.0, y, 18, 3U, 0.15, 1350/2025/2700, x, 22, 2U, 0.05, 161/161/161, y, 24, 2U, 0.025, 69/69/69, x, 26, 2U, 0.0, 0.0/0.0/0.0, y, 28, 2U, 0.025, 23/23/23, x, 30, 2U, 0.05, 258.5/258.5/258.5, y, 34, plug, -, -/-/-, -, 35, plug, -, -/-/-, -, 36, plug, -, -/-/-, -, 37, plug, -, -/-/-, -, 38, plug, -, -/-/-, -, 40, plug, -, -/-/-, -, 41, plug, -, -/-/-, -, air conditioner max. cooling capacity: 10 [kW] air conditioner airflow: 0.533 [m3/s] air conditioner inlet center: (3.76, 1.3, 3.0) air conditioner outlet center: (3.76, 2.8, 3.0) ventilation airflow: 0.0252 [m3/s] ventilation inlet center: (2.8125, 3.6475, 3.0) ventilation outlet center: (2.95, 0.605, 3.0) domain cuboid cavities (start point, end point): (0, 0, 3.0), (0.72, 4.1, 3.27), (0.32, 0, 3.27), (0.72, 3.78, 3.5) domain cuboid obstacles (start point, end point): (3.61, 0, 0), (4.86, 0.44, 1.89) (0.32, 3.78, 0), (0.72, 4.1, 3.0)   The dataset contains records of below variables: temperature from four virtual probes placed at the same locations as real sensors in the testbed:   (1.8, 2.12, 1.42) - close to inlet of a server from the first rack   (4.8, 1.65, 1.5) - close to air conditioner wall-mounted control panel   (2.5, 2.09, 0.95) - close to inlet of a server from the second rack   (2.8, 0.65, 0.75) - probe distanced from both racks and air conditioner, imitating "neutral" point surface-averaged temperature at inlet of each server surface-averaged temperature at outlet of each server surface-averaged temperature at air conditioner inlet surface-averaged temperature at air conditioner outlet
European data infrastructure with broad catalog discovery, free evaluation access and production-grade API options.
190K+
indexed dataset pages
32
countries and EU institutions
2019
API-first since
Free API quota
for evaluation and prototypes
SLA
history and push on production APIs
FAQ

Questions before production use

Practical answers on evaluation, licensing, freshness, versioning and support.

api.store is built and operated by Apitalks s.r.o. Company details and a direct contact path are linked in the footer for vendor checks and procurement review.
Yes. Selected APIs include a free API quota, so your team can validate coverage, freshness, response shape and workflow fit before asking for a production plan.
Often yes, but usage rights depend on the source license and dataset. We surface source, license and update metadata where available, and can help review terms before a production integration.
Maintained APIs include update metadata where available. For production integrations, we can add history, monitoring and push updates so changes are easier to detect and act on.
Production APIs can add SLA, stable identifiers, versioning support, history, push updates and direct support around the data your product or AI workflow depends on.

Didn't find the API you need?

Let us know and we will figure it out for you.

European data discovery with free evaluation access and production-grade API options.

Copyright © 2026. Made by Apitalks